Description

Williams AV DL207 NET Digi-Loop Medium Area Dual Channel Hearing Loop Amplifier

DL207 NET: The Hearing Loop System that Maximizes Amplifier Technology

The DL207 NET hearing loop system is an excellent solution for those looking to maximize the potential of amplifier technology. Its network-control feature allows for simple, remote setup, maintenance, and monitoring of the induction loop system using a laptop or tablet. The DSP audio processing is flexible and offers powerful software control of mixing, compression, equalization, and more. This assistive listening system is designed to meet IEC 60118-4 standards on system performance when integrated into a properly designed and installed system.

The DL207 NET system is equipped with a powerful Class D pulse-width amplifier that maximizes the system's efficiency. It also offers a dual 9.5 A rms loop output for dual loop or phased array configuration, as well as a 70-100 V input that connects to a distributed speaker/paging system, making sure that users with hearing aids won't miss any announcements.

The DL207 NET has been tested to IEC Specifications 62489-1 Benchmark Standards, providing peace of mind that the system will perform as expected.

Key Features

  • Remote control and calibration of the unit through application software
  • Continuous high current output of 9.5 Arms (13.4 Apk) per output
  • LCD screen with VU metering and easy one-button menu control
  • DSP audio processing
  • USB port for firmware updates
  • Input mixing, parametric equalization, compression, metal compensation, high and low-pass filters, AGC, and audio delay
  • Power-save mode for energy efficiency
  • Adjustable output delay for multiple amplifiers in large venues
  • Fault warning and active protection against shorted or open circuits and overheating
  • Loop fault relay output for troubleshooting
  • XLR and 3-position terminal block input configurable as microphone input or line-input, balanced or unbalanced
  • Standard 1 RU, 19" rackmount design
  • Magnetic signal coupling for devices with telecoils (T-coils) like hearing aids, cochlear implants, or optional loop receivers
  • DL207 suitable for phased-array or dual-loop systems; DL107 suitable for perimeter loop or single array
  • Phased-array mode automatically produces a 90° phase shift in slave loop output
  • Meets IEC Specification 60118-4 when properly designed and commissioned
  • Tested to IEC Specifications 62489-1 Benchmark Standards
  • Complies with ADA/ADAAG guidelines.

Technical Specifications

System Includes
(1) PLA DL207 NET - Induction Loop Amplifier
(1) WLC 004 - Line Cord (US)
(1) IDP 009 - ADA Wall Plaque (T-Coil)
Dimensions
1 RU Rackmount, 19” W x 1.75” H x 10” D. Chassis is 17” W.
Weight
DL107: 9.2 lbs (4.2 kg)
DL207: 9.2 lbs (4.2 kg)
Color
Case: Black, white and blue legends on front, white legends on back. LCD: Backlit Blue.
Fan cooling
Variable Speed, Temperature Controlled
Power supply
Internal, Universal 100-240 VAC, 50/60 Hz, 200 Watt. Fuse: 5 x 20 mm, 5 A, 250 V.
AC power plug is IEC 320-C14.
Heat output @ 120 VAC
DL107 : Sleep State: 63 BTU/hr; Idle State: 71 BTU/hr; Driving one loop @ 9.5 A: 339 BTU/hr
DL207: Sleep State: 63 BTU/hr; Idle State: 84 BTU/hr; Driving two loops @ 9.5 A each: 638 BTU/hr
Ethernet
(1x) RJ-45; 10-100 MBps.
USB
(1x) standard-B. USB 1.1, 2.0 or 3.0 supported.
Environment
0-35° C ( 32-95° F), 0-90% relative humidity,
Coverage area*
DL207 (dual output amplifier):
30,000 sq. ft. (2,786 sq. m.) (Perimeter Loops, 3:1 aspect ratio, both outputs driven)
18,000 sq. ft. (1,672 sq. m.) (Perimeter Loops, 1:1 aspect ratio, both outputs driven)

DL107 (single output amplifier):
15,000 sq. ft. (1,393 sq. m.) (Perimeter Loop, 3:1 aspect ratio)
9,000sq. ft. (836 sq. m.) (Perimeter Loop, 1:1 aspect ratio)
Dante input
On “D” models only. (1x) RJ-45;100 Mbps. Minimum latency: 2 ms. Audio sample rates supported: 44.1, 48 kHz. Resolution: 24 bits.
Line inputs
(1x) 3-position terminal block, 10 kΩ input impedance. Configurable/accepts -10 dBV, -4 dBu, +4 dBu, +8 dBu, balanced or unbalanced. Level adjustable 0 to -96 dB.
Mic/Line inputs
(1x) XLR 3-pin jack. Input impedance: 1.5 kΩ Mic, 10 kΩ Line. Configurable/Accepts: Mic, Line -10 dBV, Line +4 dBu, or Line +8 dBu, balanced or unbalanced. Phantom supply (24V).
70-100 V input
(1x) 2-position terminal block; high/speaker-level input (accepts 25 V, 70 V or 100 V) from distributed audio/paging systems.
Line outputs
(1x) 3-position terminal block; loop-through of Mic/Line Input 1 <&> Line Input 2, +4 dBu, Balanced or Unbalanced. The line outputs mirror the audio of the loop output.
Loop output(s)
(1x) 2-position terminal block per output
Audio output delay
Adjustable from 0 to 165 msec
Headphone output
(1x) 1/4” stereo headphone jack, on front of unit. Monitored input or output selectable in menu.
Loop fault relay
(1x) 3-position terminal block providing NC, NO and Common. Contact rating: 2.0 A @ 30 VDC.
Loop output drive voltage
16.1 Vrms (22.8 Vpk) continuous
Rated loop output current*
9.5 Arms (13.4 Apk) per output
Loop resistance range
0.5 Ω to 3.0 Ω (DC)
Rated load*
0.5 Ω DC with 135 µH inductance
Frequency response
45 Hz to 9.0 kHz ± 2 dB (1 kHz ref.)
Rated loop THD*
1 % at rated output current (1 kHz sine wave).
Front controls
Front LCD display menu access/adjustment via control button/dial.
Adjustable settings
Input mixing, parametric equalization, compression, metal loss compensation, high and low-pass filters, AGC and audio delay, output levels. See User Manual for adjustment range(s).
Internal calibration tools
Test tone generator with pink noise, loop current adjustment/matching. See User Manual for details.
Other features
Save/load configuration, loop test, priority input selection with adjustable threshold, loop fault relay, open/short and thermal protection. See User Manual for details.
Network control <&> firmware
Function control and calibration by DigiLoop PC App via ethernet (RJ-45). PC App requires Windows 7 or higher.
Firmware updates through USB only.
Warranty
2-year warranty against component failure and manufacturing defects. See Full Warranty statement on the website for details.
Approvals
CE, UL, ULC, FCC, Industry Canada, RoHS, WEEE, CB scheme, RCM
Standards compliance
This product is designed to meet the IEC-60118-4 standard when correctly designed, installed and commissioned.
Test Specifications provided to the IEC 62489-1 standard.

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Williams AV

Williams AV DL207 NET Digi-Loop Medium Area Dual Channel Hearing Loop Amplifier

$3,70500

Williams AV DL207 NET Digi-Loop Medium Area Dual Channel Hearing Loop Amplifier

DL207 NET: The Hearing Loop System that Maximizes Amplifier Technology

The DL207 NET hearing loop system is an excellent solution for those looking to maximize the potential of amplifier technology. Its network-control feature allows for simple, remote setup, maintenance, and monitoring of the induction loop system using a laptop or tablet. The DSP audio processing is flexible and offers powerful software control of mixing, compression, equalization, and more. This assistive listening system is designed to meet IEC 60118-4 standards on system performance when integrated into a properly designed and installed system.

The DL207 NET system is equipped with a powerful Class D pulse-width amplifier that maximizes the system's efficiency. It also offers a dual 9.5 A rms loop output for dual loop or phased array configuration, as well as a 70-100 V input that connects to a distributed speaker/paging system, making sure that users with hearing aids won't miss any announcements.

The DL207 NET has been tested to IEC Specifications 62489-1 Benchmark Standards, providing peace of mind that the system will perform as expected.

Key Features

Technical Specifications

System Includes
(1) PLA DL207 NET - Induction Loop Amplifier
(1) WLC 004 - Line Cord (US)
(1) IDP 009 - ADA Wall Plaque (T-Coil)
Dimensions
1 RU Rackmount, 19” W x 1.75” H x 10” D. Chassis is 17” W.
Weight
DL107: 9.2 lbs (4.2 kg)
DL207: 9.2 lbs (4.2 kg)
Color
Case: Black, white and blue legends on front, white legends on back. LCD: Backlit Blue.
Fan cooling
Variable Speed, Temperature Controlled
Power supply
Internal, Universal 100-240 VAC, 50/60 Hz, 200 Watt. Fuse: 5 x 20 mm, 5 A, 250 V.
AC power plug is IEC 320-C14.
Heat output @ 120 VAC
DL107 : Sleep State: 63 BTU/hr; Idle State: 71 BTU/hr; Driving one loop @ 9.5 A: 339 BTU/hr
DL207: Sleep State: 63 BTU/hr; Idle State: 84 BTU/hr; Driving two loops @ 9.5 A each: 638 BTU/hr
Ethernet
(1x) RJ-45; 10-100 MBps.
USB
(1x) standard-B. USB 1.1, 2.0 or 3.0 supported.
Environment
0-35° C ( 32-95° F), 0-90% relative humidity,
Coverage area*
DL207 (dual output amplifier):
30,000 sq. ft. (2,786 sq. m.) (Perimeter Loops, 3:1 aspect ratio, both outputs driven)
18,000 sq. ft. (1,672 sq. m.) (Perimeter Loops, 1:1 aspect ratio, both outputs driven)

DL107 (single output amplifier):
15,000 sq. ft. (1,393 sq. m.) (Perimeter Loop, 3:1 aspect ratio)
9,000sq. ft. (836 sq. m.) (Perimeter Loop, 1:1 aspect ratio)
Dante input
On “D” models only. (1x) RJ-45;100 Mbps. Minimum latency: 2 ms. Audio sample rates supported: 44.1, 48 kHz. Resolution: 24 bits.
Line inputs
(1x) 3-position terminal block, 10 kΩ input impedance. Configurable/accepts -10 dBV, -4 dBu, +4 dBu, +8 dBu, balanced or unbalanced. Level adjustable 0 to -96 dB.
Mic/Line inputs
(1x) XLR 3-pin jack. Input impedance: 1.5 kΩ Mic, 10 kΩ Line. Configurable/Accepts: Mic, Line -10 dBV, Line +4 dBu, or Line +8 dBu, balanced or unbalanced. Phantom supply (24V).
70-100 V input
(1x) 2-position terminal block; high/speaker-level input (accepts 25 V, 70 V or 100 V) from distributed audio/paging systems.
Line outputs
(1x) 3-position terminal block; loop-through of Mic/Line Input 1 <&> Line Input 2, +4 dBu, Balanced or Unbalanced. The line outputs mirror the audio of the loop output.
Loop output(s)
(1x) 2-position terminal block per output
Audio output delay
Adjustable from 0 to 165 msec
Headphone output
(1x) 1/4” stereo headphone jack, on front of unit. Monitored input or output selectable in menu.
Loop fault relay
(1x) 3-position terminal block providing NC, NO and Common. Contact rating: 2.0 A @ 30 VDC.
Loop output drive voltage
16.1 Vrms (22.8 Vpk) continuous
Rated loop output current*
9.5 Arms (13.4 Apk) per output
Loop resistance range
0.5 Ω to 3.0 Ω (DC)
Rated load*
0.5 Ω DC with 135 µH inductance
Frequency response
45 Hz to 9.0 kHz ± 2 dB (1 kHz ref.)
Rated loop THD*
1 % at rated output current (1 kHz sine wave).
Front controls
Front LCD display menu access/adjustment via control button/dial.
Adjustable settings
Input mixing, parametric equalization, compression, metal loss compensation, high and low-pass filters, AGC and audio delay, output levels. See User Manual for adjustment range(s).
Internal calibration tools
Test tone generator with pink noise, loop current adjustment/matching. See User Manual for details.
Other features
Save/load configuration, loop test, priority input selection with adjustable threshold, loop fault relay, open/short and thermal protection. See User Manual for details.
Network control <&> firmware
Function control and calibration by DigiLoop PC App via ethernet (RJ-45). PC App requires Windows 7 or higher.
Firmware updates through USB only.
Warranty
2-year warranty against component failure and manufacturing defects. See Full Warranty statement on the website for details.
Approvals
CE, UL, ULC, FCC, Industry Canada, RoHS, WEEE, CB scheme, RCM
Standards compliance
This product is designed to meet the IEC-60118-4 standard when correctly designed, installed and commissioned.
Test Specifications provided to the IEC 62489-1 standard.