Free shipping on orders above $99* Details

Same-day Shipping for most orders before 10AM PST

Trusted by Professionals Since 1991

Limited time 5% off* code: LIMITED5OFF
Ashly  |  SKU: ASH-AMP-NXE752

Ashly nXe752 | 2 Channel 75 Watts Network Power Amplifier

$2,52000
Shipping calculated at checkout.

Condition: New



Description

Ashly nXe752 2 Channel 75 Watts Network Power Amplifier

NX Multi-Mode Power Amplifiers are designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces and convention centers.

Key Features

  • Selectable 80Hz 2nd-order Hi-pass filter, limiter, and input gain per channel
  • Remote DC level control per channel
  • Extensive protection circuitry, continuously variable cooling fan
  • Ethernet port for software control and monitoring of amplifier functions, with front panel COM activity LED
  • Serial data port available for Ashly WR-5 programmable remote control (optional RS-232 converter INA-1 available for third party controllers)
  • Instant Standby Mode, 40% reduction in idle power consumption, triggered by contact closure, software control, or event scheduler
  • Preset recall via contact closure, software control, remote control, or event scheduler
  • Programmable power-on delay
  • Aux preamp line outputs for driving other amplifiers
  • Fault condition logic outputs per channel
  • Euroblock input connectors
  • Euroblock loudspeaker connectors
  • Detachable AC mains line-cord connector
  • Safety/Compliance: cTUVus (pending), CE, FCC, RoHS

Technical Specifications

Channels
2
*Max Output Power: Measured in Watts Per Channel, Low Impedance Output Mode, All Channels Driven at Rated Load
2 Ohms: 75
4 Ohms: 75
8 Ohms: 75
*Low Impedance Output Mode, Bridged Output: Measured in Watts, All Channels Driven at Rated Load
4 Ohms: 150
8 Ohms: 150
*25V, 70V, 100V Constant Voltage Output Mode: Measured in Watts, All Channels Driven at Rated Load
25V (per channel): 75
70V (per channel): 75
100V (per channel): 75
Total AC Mains Power Draw: Measured in Watts, Typical input, all channels driven, 120VAC
Sleep Mode: <1
Standby Mode: 15
Idle (no signal): 33
1/8 Max Power @ 2 Ohms: 82
Current Draw: Measured in Amps, Typical Input, Total for all Channels, 120VAC, Divide by 2 for 240VAC
Sleep Mode: 94mA
Standby Mode: 0.2
Idle (no input signal): 0.35
1/8 Max Power @ 2 Ohms: 0.76
Thermal Dissipation: BTU/hr, Typical Input, Total for all Channels
Sleep mode: 2.14
Standby mode: 51
Idle (no input signal): 112
1/8 Max Power @ 2 Ohms: 215
Voltage Gain
Selectable at 26dB, 32dB, 38dB, or 1.4V
Damping Factor
>250 (8 Ohm load <1kHz)
Input High Pass Filter
80Hz 2nd order
Distortion (SMPTE, typical)
<0.5%
Distortion (THD-N, typical)
<0.5% (8 Ohms, 10dB below rated power, 20Hz-20kHz)
Channel Separation
-75dB (dB from full output, 1kHz)
Signal-to-Noise (unweighted) 20Hz-20kHz, Gain@26dB
>99dB (all 150x models)
>96dB (all 75x models)
Frequency Response
20Hz-20kHz, +/-0.05dB
Balanced Input Connector
Euroblock 3.5mm
Input Impedance
10k Ohms
Maximum Input Level
+21dBu
Speaker Output Connector
Euroblock 7.62mm
Control Network
RJ-45 connector, 100MB Ethernet
AUX Output Connector
Balanced Euroblock 3.5mm
AUX Output Maximum Level
+21dBu
Remote Standby Contact Closure
Euroblock 3.5mm, close contact pin to ground (G) for standby mode
Preset Recall Contact Closure
Euroblock 3.5mm, close contact to ground (G) for preset 1-4 recall
Data Connection
Euroblock 3.5mm Gnd, +18V, Data Out, Data In
Fault Condition Logic Outputs
Euroblock 3.5mm fault indicated by loss of 1Hz "heartbeat" pulse signal
Remote DC Level Control
Euroblock 3.5mm Gnd, CV, V+ per input
Attenuators (per channel)
Rear panel, software, offset link group, remote control. Fully off = Mute
Amplifier Protection
Shorted output power limiting, over-temperature, DC-output, power-supply fault, mains-fuses & inrush-current limiting
Cooling
Continuously variable temperature controlled fan
Environmental
32°F-120°F, (0°C-49°C) non-condensing
Nominal Voltage Input
100 - 240VAC
Operating Range
70 - 270VAC
Minimum power-up
70VAC
Power Supply Type
SMPS with active PFC
(Power Factor Correction)
AC Mains Line Cord Connector
Detachable Nema 5-15 for USA
(May vary for export)
Unit Dimensions
19”W x 1.75”H x 14.54”D (483mm x 45mm x 369mm)
Unit Weight
1504/754 13.0lbs (5.4kg), 1502/752 11.9lbs (5.2kg)

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Ashly

Ashly nXe752 | 2 Channel 75 Watts Network Power Amplifier

$2,52000

Ashly nXe752 2 Channel 75 Watts Network Power Amplifier

NX Multi-Mode Power Amplifiers are designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces and convention centers.

Key Features

Technical Specifications

Channels
2
*Max Output Power: Measured in Watts Per Channel, Low Impedance Output Mode, All Channels Driven at Rated Load
2 Ohms: 75
4 Ohms: 75
8 Ohms: 75
*Low Impedance Output Mode, Bridged Output: Measured in Watts, All Channels Driven at Rated Load
4 Ohms: 150
8 Ohms: 150
*25V, 70V, 100V Constant Voltage Output Mode: Measured in Watts, All Channels Driven at Rated Load
25V (per channel): 75
70V (per channel): 75
100V (per channel): 75
Total AC Mains Power Draw: Measured in Watts, Typical input, all channels driven, 120VAC
Sleep Mode: <1
Standby Mode: 15
Idle (no signal): 33
1/8 Max Power @ 2 Ohms: 82
Current Draw: Measured in Amps, Typical Input, Total for all Channels, 120VAC, Divide by 2 for 240VAC
Sleep Mode: 94mA
Standby Mode: 0.2
Idle (no input signal): 0.35
1/8 Max Power @ 2 Ohms: 0.76
Thermal Dissipation: BTU/hr, Typical Input, Total for all Channels
Sleep mode: 2.14
Standby mode: 51
Idle (no input signal): 112
1/8 Max Power @ 2 Ohms: 215
Voltage Gain
Selectable at 26dB, 32dB, 38dB, or 1.4V
Damping Factor
>250 (8 Ohm load <1kHz)
Input High Pass Filter
80Hz 2nd order
Distortion (SMPTE, typical)
<0.5%
Distortion (THD-N, typical)
<0.5% (8 Ohms, 10dB below rated power, 20Hz-20kHz)
Channel Separation
-75dB (dB from full output, 1kHz)
Signal-to-Noise (unweighted) 20Hz-20kHz, Gain@26dB
>99dB (all 150x models)
>96dB (all 75x models)
Frequency Response
20Hz-20kHz, +/-0.05dB
Balanced Input Connector
Euroblock 3.5mm
Input Impedance
10k Ohms
Maximum Input Level
+21dBu
Speaker Output Connector
Euroblock 7.62mm
Control Network
RJ-45 connector, 100MB Ethernet
AUX Output Connector
Balanced Euroblock 3.5mm
AUX Output Maximum Level
+21dBu
Remote Standby Contact Closure
Euroblock 3.5mm, close contact pin to ground (G) for standby mode
Preset Recall Contact Closure
Euroblock 3.5mm, close contact to ground (G) for preset 1-4 recall
Data Connection
Euroblock 3.5mm Gnd, +18V, Data Out, Data In
Fault Condition Logic Outputs
Euroblock 3.5mm fault indicated by loss of 1Hz "heartbeat" pulse signal
Remote DC Level Control
Euroblock 3.5mm Gnd, CV, V+ per input
Attenuators (per channel)
Rear panel, software, offset link group, remote control. Fully off = Mute
Amplifier Protection
Shorted output power limiting, over-temperature, DC-output, power-supply fault, mains-fuses & inrush-current limiting
Cooling
Continuously variable temperature controlled fan
Environmental
32°F-120°F, (0°C-49°C) non-condensing
Nominal Voltage Input
100 - 240VAC
Operating Range
70 - 270VAC
Minimum power-up
70VAC
Power Supply Type
SMPS with active PFC
(Power Factor Correction)
AC Mains Line Cord Connector
Detachable Nema 5-15 for USA
(May vary for export)
Unit Dimensions
19”W x 1.75”H x 14.54”D (483mm x 45mm x 369mm)
Unit Weight
1504/754 13.0lbs (5.4kg), 1502/752 11.9lbs (5.2kg)