Tripp Lite SMART700HG 700VA 450W UPS Smart Tower AVR Hospital Medical 120V USB DB9

Tripp Lite's SMART 700HG offers medical-grade UPS protection with built-in line interactive voltage regulation, intelligent monitoring and unattended shutdown capability. UL 60601-1 listed as medical electrical equipment. Built-in isolation transformer with Faraday shield removes common mode noise while maintaining full AC surge suppression in all modes less than 100 microamps. Resistant to electrostatic discharge. Includes high quality hospital-grade plug and outlets. 700VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143 back to normal 120V levels, saving battery reserves for use only during complete power failures. Includes 4 outlets, diagnostic LEDs and built-in USB & RS-232 communications ports that work with downloadable PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.

Key Features

  • Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed medical electrical equipment is required
  • Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes
  • Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery power
  • Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections
  • Full line isolation offers a higher degree of safety and prevents operational problems in sensitive electronic equipment
  • Resistant to electrostatic discharge
  • Supports loads up to 700VA/450 watts
  • 42 minutes half load runtime (with 350VA load), 18 minutes full load runtime (with 700VA load)
  • 4 protected hospital-grade outlets; 6-ft. cord
  • RS-232 and USB monitoring ports for remote monitoring and unattended shutdown
  • PowerAlert unattended shutdown software available via free download from www.tripplite.com (cabling included)
  • Complete surge protection, line isolation and EMI/RFI noise filtering
  • 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace
  • Battery replacement door and back panel grounding lug

Technical Specifications

OUTPUT
Output Volt Amp Capacity (VA)
700
Output Watt Capacity (Watts)
450
Power Factor
0.6
Nominal Output Voltage(s) Supported
115V; 120V
Frequency Compatibility
60 Hz
Output Voltage Regulation (Line Mode)
-18%, +8%
Output Voltage Regulation (Battery Mode)
115V (+/- 5%)
Output Receptacles
(4) 5-15R
Output Receptacle Details
Hospital grade
Output AC Waveform (AC Mode)
Sine wave
Output AC Waveform (Battery Mode)
PWM sine wave
INPUT
Rated input current (Maximum Load)
5.5A
Nominal Input Voltage(s) Supported
120V AC
UPS Input Connection Type
5-15P-HG
Input Circuit Breakers
10A
UPS Input Cord Length (ft.
6
Recommended Electrical Service
15A 120V
Input Cord Length (ft.
6
Input Phase
Single-Phase
BATTERY
Full Load Runtime (min.)
18 min. (450w)
Half Load Runtime (min.)
42 min. (225w)
DC System Voltage (VDC)
36
Battery Recharge Rate (Included Batteries)
Less than 4 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge
RBC53
Battery Replacement Description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Overvoltage Correction: Input voltages between 126 and 143 are reduced by 9%
Undervoltage Correction: Input voltages between 96 and 106 are boosted by 10%
Severe Undervoltage Correction: Input voltages between 81 and 95 are boosted by 21%
LEDS ALARMS & SWITCHES
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
480
UPS AC Suppression Response Time
Instantaneous
EMI / RFI AC Noise Suppression
Yes
AC Suppression Joule Rating
480
AC Suppression Response Time
Instantaneous
ISOLATION
Hospital grade load isolation transformer
Leakage Current Equal to 100 microamps
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
97.7
Battery Mode BTU / Hr. (Full Load)
189.1
AC Mode Efficiency Rating (100% Load)
94%
COMMUNICATIONS
Communications Interface
USB; DB9 Serial
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions
PowerAlert Software Included
Communications Cable
USB and DB9 serial cabling included

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Tripp Lite

Tripp Lite SMART700HG 700VA 450W UPS Smart Tower AVR Hospital Medical 120V USB DB9

$1,00100

Tripp Lite SMART700HG 700VA 450W UPS Smart Tower AVR Hospital Medical 120V USB DB9

Tripp Lite's SMART 700HG offers medical-grade UPS protection with built-in line interactive voltage regulation, intelligent monitoring and unattended shutdown capability. UL 60601-1 listed as medical electrical equipment. Built-in isolation transformer with Faraday shield removes common mode noise while maintaining full AC surge suppression in all modes less than 100 microamps. Resistant to electrostatic discharge. Includes high quality hospital-grade plug and outlets. 700VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143 back to normal 120V levels, saving battery reserves for use only during complete power failures. Includes 4 outlets, diagnostic LEDs and built-in USB & RS-232 communications ports that work with downloadable PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.

Key Features

Technical Specifications

OUTPUT
Output Volt Amp Capacity (VA)
700
Output Watt Capacity (Watts)
450
Power Factor
0.6
Nominal Output Voltage(s) Supported
115V; 120V
Frequency Compatibility
60 Hz
Output Voltage Regulation (Line Mode)
-18%, +8%
Output Voltage Regulation (Battery Mode)
115V (+/- 5%)
Output Receptacles
(4) 5-15R
Output Receptacle Details
Hospital grade
Output AC Waveform (AC Mode)
Sine wave
Output AC Waveform (Battery Mode)
PWM sine wave
INPUT
Rated input current (Maximum Load)
5.5A
Nominal Input Voltage(s) Supported
120V AC
UPS Input Connection Type
5-15P-HG
Input Circuit Breakers
10A
UPS Input Cord Length (ft.
6
Recommended Electrical Service
15A 120V
Input Cord Length (ft.
6
Input Phase
Single-Phase
BATTERY
Full Load Runtime (min.)
18 min. (450w)
Half Load Runtime (min.)
42 min. (225w)
DC System Voltage (VDC)
36
Battery Recharge Rate (Included Batteries)
Less than 4 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge
RBC53
Battery Replacement Description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Overvoltage Correction: Input voltages between 126 and 143 are reduced by 9%
Undervoltage Correction: Input voltages between 96 and 106 are boosted by 10%
Severe Undervoltage Correction: Input voltages between 81 and 95 are boosted by 21%
LEDS ALARMS & SWITCHES
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
480
UPS AC Suppression Response Time
Instantaneous
EMI / RFI AC Noise Suppression
Yes
AC Suppression Joule Rating
480
AC Suppression Response Time
Instantaneous
ISOLATION
Hospital grade load isolation transformer
Leakage Current Equal to 100 microamps
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
97.7
Battery Mode BTU / Hr. (Full Load)
189.1
AC Mode Efficiency Rating (100% Load)
94%
COMMUNICATIONS
Communications Interface
USB; DB9 Serial
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions
PowerAlert Software Included
Communications Cable
USB and DB9 serial cabling included

View product