Free shipping on orders above $99* Details

Same-day Shipping for most orders before 10AM PST

Trusted by Professionals Since 1991

Limited time 5% off* code: LIMITED5OFF
VUE Audiotechnik  |  SKU: VUE-HM108A

VUE Audiotechnik hm-108a Single 8-Inch Powered Stage Monitor

$3,87500
Shipping calculated at checkout.

Condition: New



Description

VUE Audiotechnik hm-108a Single 8-Inch Powered Stage Monitor

Thoughtful cabinet design ensures that the hm monitors offer minimal visual intrusion between audience and performer. Their uniquely low profile ensures that coveted sight lines are preserved for set designers and video producers alike, while also reducing required truck space when it’s time to pack up and go.

Key Features

  • Wide 70 x 40 coverage
  • Neodymium HF compression driver with Truextent beryllium diaphragm for exceptional high-frequency clarity and output
  • Integrated internal VUEDrive System Engine equipped with 64-bit digital processor and tons of fanless amplifier horsepower and universal mains operation (85V to 260V) Optimized coverage for real-world stage monitoring use
  • Analogue, AES/EBU and Dante inputs along with build in Ethernet network switch for loop-though audio on networking. Full network monitoring and control via SystemVUE software.
  • Very low-profile and rugged birch ply-hardwood enclosure with 12-layer coating Dura-Coat LX finish provides clear sight lines and years of reliable service

Technical Specifications

DESCRIPTION
Single 8-inch Wide Coverage Monitor System
ACOUSTIC DATA
Frequency Response (+- 2.5 dB)
75 Hz to 21 kHz
Frequency Range (-10dB)
50Hz - 26 kHz
Sensitivity (1W/1m)
94 dB SPL
Max Peak SPL
122 dB SPL Long Term band limited pink noise 6 dB crest factor
Max SPL Long Term
116 dB SPL (AVG SPL @1M before protection band limited pink noise)
131 dB SPL Music Program Transient Peak
Coverage Horizontal
70 degrees - 6 dB
Coverage Vertical
45 degrees - 6dB
AMPLIFIER DATA
Amplifier Power (Long Term Sine Wave before protection)
LF: 275 watts rms
HF: 40 watts rms
Amplifier Power ( AVG Burst@ 1% THD)
LF: 600 watts rms
HF: 300 watts rms
Amplifier Protection
Input limiter, short circuit protection, DC protection of output, under & over voltage
protection, intelligent mains fuse protection, power stage overload protection,
temperature protection of transformers and heat-sinks
Operational Voltage
Universal Mains, 85-268V (dual voltage auto selection). UREC power supply integrated
amplifier modules provides universal mains operation for 120 V and 230 V, eliminating the need
for market specific self-powered loudspeakers and related reliability issues
THD+N (typical)
< 0.05 % (20 Hz - 20 kHz, 3 dB below rated power)
DSP
96k Hz sample rate, mixed-mode 64-bit digital processing, 120 dB dynamic range, less than 600 microseconds latency
Network
Ethernet / IP DHCP (or fixed IP) for remote monitoring and control
TRANSDUCER DATA
LF Driver Description
8-inch driver 3-in voice coil
HF Driver Description
1-inch exit 34 mm voice coil, Pure Truextent beryllium diaphragm
PHYSICAL DATA
Inputs
Female XLR input with male XLR loop output for both Analog input and AES EBU digital input (default digital AES channel 1, channel 2 selectable remotely via software). If clock is present system uses AES digital input. System will fall back on analog input if clock is not present. Dante Network Audio Streams via ethernet (software Selectable).
Cabinet Material
Muli-ply wood birch hardwood
Cabinet Surface
12 Step Dura-Coat LX
Dimensions (H x W x D)
11.41 x 18.81 x 11.40 in (289.8 x 478.0 x 289.5 mm)
Weight
Net: 40.6 lbs (1.8.41 kg) / Shipped: N/A

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

VUE Audiotechnik

VUE Audiotechnik hm-108a Single 8-Inch Powered Stage Monitor

$3,87500

VUE Audiotechnik hm-108a Single 8-Inch Powered Stage Monitor

Thoughtful cabinet design ensures that the hm monitors offer minimal visual intrusion between audience and performer. Their uniquely low profile ensures that coveted sight lines are preserved for set designers and video producers alike, while also reducing required truck space when it’s time to pack up and go.

Key Features

Technical Specifications

DESCRIPTION
Single 8-inch Wide Coverage Monitor System
ACOUSTIC DATA
Frequency Response (+- 2.5 dB)
75 Hz to 21 kHz
Frequency Range (-10dB)
50Hz - 26 kHz
Sensitivity (1W/1m)
94 dB SPL
Max Peak SPL
122 dB SPL Long Term band limited pink noise 6 dB crest factor
Max SPL Long Term
116 dB SPL (AVG SPL @1M before protection band limited pink noise)
131 dB SPL Music Program Transient Peak
Coverage Horizontal
70 degrees - 6 dB
Coverage Vertical
45 degrees - 6dB
AMPLIFIER DATA
Amplifier Power (Long Term Sine Wave before protection)
LF: 275 watts rms
HF: 40 watts rms
Amplifier Power ( AVG Burst@ 1% THD)
LF: 600 watts rms
HF: 300 watts rms
Amplifier Protection
Input limiter, short circuit protection, DC protection of output, under & over voltage
protection, intelligent mains fuse protection, power stage overload protection,
temperature protection of transformers and heat-sinks
Operational Voltage
Universal Mains, 85-268V (dual voltage auto selection). UREC power supply integrated
amplifier modules provides universal mains operation for 120 V and 230 V, eliminating the need
for market specific self-powered loudspeakers and related reliability issues
THD+N (typical)
< 0.05 % (20 Hz - 20 kHz, 3 dB below rated power)
DSP
96k Hz sample rate, mixed-mode 64-bit digital processing, 120 dB dynamic range, less than 600 microseconds latency
Network
Ethernet / IP DHCP (or fixed IP) for remote monitoring and control
TRANSDUCER DATA
LF Driver Description
8-inch driver 3-in voice coil
HF Driver Description
1-inch exit 34 mm voice coil, Pure Truextent beryllium diaphragm
PHYSICAL DATA
Inputs
Female XLR input with male XLR loop output for both Analog input and AES EBU digital input (default digital AES channel 1, channel 2 selectable remotely via software). If clock is present system uses AES digital input. System will fall back on analog input if clock is not present. Dante Network Audio Streams via ethernet (software Selectable).
Cabinet Material
Muli-ply wood birch hardwood
Cabinet Surface
12 Step Dura-Coat LX
Dimensions (H x W x D)
11.41 x 18.81 x 11.40 in (289.8 x 478.0 x 289.5 mm)
Weight
Net: 40.6 lbs (1.8.41 kg) / Shipped: N/A

View product