Free shipping on orders above $99* Details

Same-day Shipping for most orders before 10AM PST

Trusted by Professionals Since 1991

Limited time 5% off* code: LIMITED5OFF
DPA  |  SKU: DPA-2015

DPA 2015 Wide Cardioid Condenser Microphone

$1,01880
Shipping calculated at checkout.

Condition: New



Description

DPA 2015 Wide Cardioid Condenser Microphone

The 2015 Compact Wide Cardioid Microphone is for ambient pick up of a drum kit or other instrument groups.

In a live situation when a conventional cardioid pattern isn’t quite open enough, choose a pair of 2015 Compact Wide Cardioids. They work ideally as overheads to capture a balanced sound of the entire group of instruments, like a drum kit.

Also, when recording instrument groups with complex radiation patterns, the wide cardioid (also known as hemispheric, subcardioid or hypocardioid) design covers a greater sound angle and is an excellent choice.

Durable, reinforced construction
The 2015 is constructed to withstand rough handling on a hectic live stage. It has a thicker, more robust body construction of brass that is very durable and known for its corrosion resistance and tolerance against metal fatigue. In addition to the heavy-duty materials used, the surfaces of the mic handle and grille are treated with a protective black chrome finish, which ensures more graceful ageing.

Uniform cardioid directionality
The 2015 has a wide cardioid capsule with DPA’s famously flat off-axis response. Besides a high gain-before-feedback, this characteristic makes it easier for sound engineers to handle bleed from other instruments at close proximity. The 2015 picks up off-axis sounds in a very natural and attenuated way.

Spacious, wide cardioid pick-up pattern
The 2015 can be positioned near the drum kit, closer than you would normally place overhead microphones, and still capture sound evenly across the entire drum kit. This closer position results in stronger signal from the drum kit and therefore less bleed from the stage.

Natural and precise sound reproduction
Like all other DPA microphones, the 2015 delivers pure, transparent sound quality.

Compact design for unobtrusive placement on stage
Although the 2015 can be purchased as a single mic, it really shines as a matched stereo pair, selected with +/- 1.5 dB sensitivity tolerance. The compact design of this stereo pair ensures an open, natural sound pick-up without blocking any of the exciting action on stage.

Key Features

  • Durable, reinforced construction
  • Uniform wide cardioid directionality
  • Spacious sound due to a wide cardioid pick-up pattern
  • Natural and precise sound reproduction
  • Compact design for unobtrusive placement on stage

Technical Specifications

Directional pattern
Wide cardioid
Principle of operation
Pressure gradient
Cartridge type
Pre-polarized condenser
Frequency response
20 Hz - 20 kHz
Effective frequency range, ±2 dB, at 30 cm (11.8 in)
40 Hz to 18 kHz
Sensitivity, nominal, ±2 dB at 1 kHz
12 mV/Pa; -37.7 dB re. 1 V/Pa
Equivalent noise level, A-weighted
Typ. 18 dB(A) re 20 µPa (max. 20 dB(A))
Distortion, THD < 1%
147 dB SPL (150 dB SPL peak)
Dynamic range
Typ. 132 dB
Max. SPL, THD 10%
150 dB SPL (153 dB SPL peak)
Rated output impedance
60 Ω
Minimum load impedance
2 kΩ
Cable drive capability
100 m (328 ft)
Output balance principle
Impedance balancing with Active Drive
Common mode rejection ratio (CMRR)
> 60 dB
Power supply (for full performance)
P48 (Phantom Power)
Current consumption
0.7 mA
Connector
XLR-3M. Pin 1: shield, Pin 2: signal + phase, Pin 3: - phase
Color
Matte black
Weight
83 g (2.9 oz)
Microphone diameter
19 mm (0.75 in)
Capsule diameter
17 mm (0.67 in)
Microphone length
94 mm (3.7 in)
Maximum output voltage, RMS
8.7 V (21 dBu)
Polarity
+V at pin 2 for positive sound pressure
Temperature range
-40 Degrees C to 45 Degrees C (-40 Degrees F to 113 Degrees F)
Relative humidity (RH)
Up to 90%
Sensitivity selection tolerance (at 1 kHz)
±1.5 dB

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

DPA

DPA 2015 Wide Cardioid Condenser Microphone

$1,01880

DPA 2015 Wide Cardioid Condenser Microphone

The 2015 Compact Wide Cardioid Microphone is for ambient pick up of a drum kit or other instrument groups.

In a live situation when a conventional cardioid pattern isn’t quite open enough, choose a pair of 2015 Compact Wide Cardioids. They work ideally as overheads to capture a balanced sound of the entire group of instruments, like a drum kit.

Also, when recording instrument groups with complex radiation patterns, the wide cardioid (also known as hemispheric, subcardioid or hypocardioid) design covers a greater sound angle and is an excellent choice.

Durable, reinforced construction
The 2015 is constructed to withstand rough handling on a hectic live stage. It has a thicker, more robust body construction of brass that is very durable and known for its corrosion resistance and tolerance against metal fatigue. In addition to the heavy-duty materials used, the surfaces of the mic handle and grille are treated with a protective black chrome finish, which ensures more graceful ageing.

Uniform cardioid directionality
The 2015 has a wide cardioid capsule with DPA’s famously flat off-axis response. Besides a high gain-before-feedback, this characteristic makes it easier for sound engineers to handle bleed from other instruments at close proximity. The 2015 picks up off-axis sounds in a very natural and attenuated way.

Spacious, wide cardioid pick-up pattern
The 2015 can be positioned near the drum kit, closer than you would normally place overhead microphones, and still capture sound evenly across the entire drum kit. This closer position results in stronger signal from the drum kit and therefore less bleed from the stage.

Natural and precise sound reproduction
Like all other DPA microphones, the 2015 delivers pure, transparent sound quality.

Compact design for unobtrusive placement on stage
Although the 2015 can be purchased as a single mic, it really shines as a matched stereo pair, selected with +/- 1.5 dB sensitivity tolerance. The compact design of this stereo pair ensures an open, natural sound pick-up without blocking any of the exciting action on stage.

Key Features

Technical Specifications

Directional pattern
Wide cardioid
Principle of operation
Pressure gradient
Cartridge type
Pre-polarized condenser
Frequency response
20 Hz - 20 kHz
Effective frequency range, ±2 dB, at 30 cm (11.8 in)
40 Hz to 18 kHz
Sensitivity, nominal, ±2 dB at 1 kHz
12 mV/Pa; -37.7 dB re. 1 V/Pa
Equivalent noise level, A-weighted
Typ. 18 dB(A) re 20 µPa (max. 20 dB(A))
Distortion, THD < 1%
147 dB SPL (150 dB SPL peak)
Dynamic range
Typ. 132 dB
Max. SPL, THD 10%
150 dB SPL (153 dB SPL peak)
Rated output impedance
60 Ω
Minimum load impedance
2 kΩ
Cable drive capability
100 m (328 ft)
Output balance principle
Impedance balancing with Active Drive
Common mode rejection ratio (CMRR)
> 60 dB
Power supply (for full performance)
P48 (Phantom Power)
Current consumption
0.7 mA
Connector
XLR-3M. Pin 1: shield, Pin 2: signal + phase, Pin 3: - phase
Color
Matte black
Weight
83 g (2.9 oz)
Microphone diameter
19 mm (0.75 in)
Capsule diameter
17 mm (0.67 in)
Microphone length
94 mm (3.7 in)
Maximum output voltage, RMS
8.7 V (21 dBu)
Polarity
+V at pin 2 for positive sound pressure
Temperature range
-40 Degrees C to 45 Degrees C (-40 Degrees F to 113 Degrees F)
Relative humidity (RH)
Up to 90%
Sensitivity selection tolerance (at 1 kHz)
±1.5 dB

View product